Transite cement shingle siding
Transite shingles are hard, gray or painted cement panels, sometimes with a slightly textured face, nailed in overlapping courses. The district classes them as Category II nonfriable material: not regulated while intact. Removal therefore means wetting, cutting or pulling the nails and lowering each panel by hand, then wrapping the stack. Panels that are cracked, weathered to a soft surface or already shattered need more containment and may be handled as regulated waste.